Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
Biomed Res Int ; 2021: 7343147, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34540997

RESUMO

This study was aimed at fabricating and evaluating the physical and bioproperties of nanofast cement (NFC) as a replacement of the MTA. The cement particles were decreased in nanoscale, and zirconium oxide was used as a radiopacifier. The setting time and radiopacity were investigated according to ISO recommendations. Analysis of color, bioactivity, and cytotoxicity was performed using spectroscopy, simulated body fluid (SBF), and MTT assay. The setting time of cement pastes significantly dropped from 65 to 15 min when the particle sizes decreased from 2723 nm to 322 nm. Nanoparticles provide large surface areas and nucleation sites and thereby a higher hydration rate, so they reduced the setting time. Based on the resulting spectroscopy, the specimens did not exhibit clinically noticeable discoloration. Resistance to discoloration may be due to the resistance of zirconium oxide to decomposition. Scanning electron microscopy (SEM), X-ray diffraction (XRD), and infrared spectroscopy (FTIR) examinations of the immersed SBF samples showed apatite formation that was a reason for its suitable bioactivity. The results of cell culture revealed that NFC is nontoxic. This study showed that NFC was more beneficial than MTA in dental restorations.


Assuntos
Cimentos Dentários/química , Restauração Dentária Permanente/métodos , Nanoestruturas/química , Bismuto/química , Cimentos Ósseos/análise , Cimentos Ósseos/química , Compostos de Cálcio/química , Hidróxido de Cálcio/química , Cimentos Dentários/análise , Cimentos de Ionômeros de Vidro/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Propriedades de Superfície , Água/química , Difração de Raios X , Zircônio/química
2.
Iowa Orthop J ; 40(1): 191-193, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32754006

RESUMO

Background: Exposure to methyl methacrylate vapor (MMA) presents an occupational risk to orthopedic surgeons and ancillary personnel in the operating room. The purpose of this study was to identify a disposable face mask to reduce MMA organic vapor inhalation in the operative suite. Methods: First, the effectiveness of MMA vapor filtration was determined in the laboratory. A section of activated carbon impregnated filter face mask (Model 8514, 3M Inc.) was exposed to 150 ppm MMA vapor and MMA ppm of filtered air was monitored until MMA vapor was detectable. The face mask was then worn as directed in the operating room during routine cement mixing during total knee arthroplasty to determine the exposure to MMA vapors during the procedure both with and without the activated carbon impregnated filter face mask. Results: The activated carbon impregnated face mask was effective in reducing MMA vapor inhalation to non-detectable levels for up to 40 minutes in the laboratory at steady-state exposure of 150 ppm MMA vapor as well as throughout cement mixing and curing in the operative suite during routine total knee arthroplasty. Conclusions: An activated carbon impregnated face mask offers a solution for the orthopedic surgeon and supporting personnel who wish to limit their exposure to MMA vapors due to health concerns.Level of Evidence: III.


Assuntos
Poluentes Ocupacionais do Ar/análise , Cimentos Ósseos/análise , Exposição por Inalação/prevenção & controle , Máscaras , Metilmetacrilato/análise , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Artroplastia do Joelho , Humanos , Salas Cirúrgicas , Melhoria de Qualidade
3.
Folia Microbiol (Praha) ; 65(3): 475-482, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31654320

RESUMO

Vancomycin is often used in orthopedic surgery as a local prophylaxis of bacterial infection. The aim of this work was to compare the release of vancomycin and its biologically inactive crystalline degradation products (CDP-1) during in vitro experiments from different types of local antibiotic delivery systems (bone grafts and bone cements). The concentrations of vancomycin and its crystalline degradation products were determined by high-performance liquid chromatography. Each experiment was performed in a phosphate buffer solution over 21 days. Morselized bone grafts, synthetic bone cements Palacos and Copal, and synthetic bone grafts were tested as local carriers of vancomycin. The highest concentration approximately 670 mg/L of vancomycin was released from synthetic bone grafts Actifuse. Even after 21 days, the concentration of vancomycin was still above the minimum inhibitory concentration (MIC). The maximum concentration of vancomycin released in two experiments with human bone grafts exceeded 600 mg/L during the first day and was still above MIC level 21 days later when the experiment was concluded. By comparing the synthetic bone cements Palacos and Copal, Copal had the average maximum concentration of only 32.4 mg/L and Palacos 35.7 mg/L. The concentration of vancomycin fell below the MIC for vancomycin-resistant Staphylococcus aureus (VRSA) on the seventh day with Palacos and the ninth day with Copal. This study showed the insufficient concentration of released vancomycin from synthetic bone cements at the end of the experiment. For improvement of local prophylaxis, it would be beneficial to increase the amount of vancomycin in bone cements.


Assuntos
Antibacterianos/análise , Antibacterianos/metabolismo , Cimentos Ósseos/análise , Vancomicina/análise , Vancomicina/metabolismo , Transplante Ósseo , Cromatografia Líquida de Alta Pressão , Humanos , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Testes de Sensibilidade Microbiana
4.
Colloids Surf B Biointerfaces ; 183: 110406, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31401462

RESUMO

Amphotericin B is used for local delivery from polymethylmethacrylate to treat fungal prosthetic joint infections. The optimal amphotericin B formulation and the influence of different poragens in the bone cements are unknown. To investigate the necessary amount of amphotericin B in the bone cement to prevent Candida biofilm several amphotericin B formulations were studied: non-liposomal and liposomal with or without poragen gentamicin. For the non-liposomal formulation, standard bile salt, the sodium deoxycholate, was used and additionally N-methyl-D-glucamine/palmitate was applied. The activity of the released amphotericin B was tested against C. albicans, C. glabrata, C. parapsilosis and C. krusei biofilms with application of the isothermal calorimeter and standard microbiological methods. Compressive strength was measured before and after antifungal elution from the cements. There is less aggregated N-methyl-D-glucamine/palmitate amphotericin B released but its antifungal activity is equivalent with the deoxycholate amphotericin B. The minimum quantity of antifungal preventing the Candida biofilm formation is 12.5 mg in gram of polymer powder for both non-liposomal formulations. The addition of gentamicin reduced the release of sodium deoxycholate amphotericin B. Gentamicin can be added to N-methyl-D-glucamine/palmitate amphotericin B in order to boost the antifungal release. When using liposomal amphotericin B more drug is released. All amphotericin B formulations were active against Candida biofilms. Although compressive strength slightly decreased, the obtained values were above the level of strength recommended for the implant fixation. The finding of this work might be beneficial for the treatment of the prosthetic joint infections caused by Candida spp.


Assuntos
Anfotericina B/análogos & derivados , Anfotericina B/farmacologia , Antifúngicos/farmacologia , Biofilmes/efeitos dos fármacos , Candida albicans/efeitos dos fármacos , Ácido Desoxicólico/farmacologia , Anfotericina B/química , Antifúngicos/química , Biofilmes/crescimento & desenvolvimento , Cimentos Ósseos/análise , Cimentos Ósseos/química , Candida albicans/crescimento & desenvolvimento , Candida glabrata/efeitos dos fármacos , Candida glabrata/crescimento & desenvolvimento , Candida parapsilosis/efeitos dos fármacos , Candida parapsilosis/crescimento & desenvolvimento , Força Compressiva , Ácido Desoxicólico/química , Combinação de Medicamentos , Liberação Controlada de Fármacos , Gentamicinas/farmacologia , Cinética , Teste de Materiais , Testes de Sensibilidade Microbiana , Polimetil Metacrilato/análise , Polimetil Metacrilato/química , Porosidade
5.
Spine J ; 18(12): 2297-2301, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30075299

RESUMO

BACKGROUND CONTEXT: Intravertebral clefts (IVCs) are vacuum-like cavities commonly associated with osteoporotic vertebral compression fractures (OVCFs). IVCs promote cement leakage during kyphoplasty, suggesting a physical link with the basivertebral foramen, although this is uncertain. PURPOSE: The present study aims to create IVCs in mechanical experiments on cadaveric spines in order to clarify their pathogenesis, structure, and links with the basivertebral foramen. STUDY DESIGN AND METHODS: In total, 15 three-vertebra lumbar specimens from five cadavers aged 68 to 71 years were subjected to axial compressive overload followed by cyclic loading in flexion and extension to create an OVCF together with an IVC. Computed tomography scans and radiographs were used to confirm structural changes and micro-CT was used to measure trabecular bone properties in five specimens. Unipedicular vertebroplasty was then performed on 10 damaged specimens until fluoroscopy revealed extravasation of cement. RESULTS: In every specimen, loading created an OVCF with an IVC. Dissection and imaging showed that the IVC was always connected with the basivertebral foramen. The central vertebral region, including the IVC, had the lowest connectivity density, trabecular number, and bone volume fraction, and the highest trabecular separation. Vertebroplasty caused cement leakage through the basivertebral foramen in nine specimens and into an adjacent disc in one specimen. CONCLUSION: Cyclic loading in flexion and extension applied to a fractured osteoporotic vertebra can create an IVC, which then allows cement leakage via the basivertebral foramen.


Assuntos
Fraturas por Compressão/fisiopatologia , Vértebras Lombares/fisiopatologia , Fraturas por Osteoporose/fisiopatologia , Fraturas da Coluna Vertebral/fisiopatologia , Idoso , Cimentos Ósseos/análise , Cadáver , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Radiografia , Estudos Retrospectivos , Fraturas da Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X , Malha Trabecular/diagnóstico por imagem
6.
Eur Spine J ; 27(8): 1775-1784, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29497852

RESUMO

PURPOSE: Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. METHODS: In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm3 ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm3 ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. RESULTS: The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard titanium screws (3701 ± 1228 vs. 3751 ± 1614 load cycles, p = 0.89). PMMA cement augmentation of CF/PEEK pedicle screws furthermore significantly increased the mean number of load cycles until loosening by 1.63-fold (5100 ± 1933 in augmented vs. 3130 ± 2132 in nonaugmented CF/PEEK screws, p = 0.015). In addition, angular screw motion assessed by stress fluoroscopy was significantly smaller in augmented than in nonaugmented CF/PEEK screws before as well as after failure. CONCLUSIONS: Using nonmetallic CF/PEEK instead of standard titanium as pedicle screw material did not affect screw loosening in the chosen test setup, whereas cement augmentation enhanced screw anchorage of CF/PEEK screws. While comparable to titanium screws in terms of screw loosening, radiolucent CF/PEEK pedicle screws offer the significant advantage of not interfering with postoperative imaging and radiotherapy. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Vértebras Lombares/cirurgia , Parafusos Pediculares/efeitos adversos , Desenho de Prótese/métodos , Falha de Prótese/etiologia , Idoso , Idoso de 80 Anos ou mais , Benzofenonas , Fenômenos Biomecânicos , Cimentos Ósseos/análise , Cadáver , Fibra de Carbono/análise , Feminino , Fluoroscopia/métodos , Humanos , Cetonas/análise , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Parafusos Pediculares/estatística & dados numéricos , Polietilenoglicóis/análise , Polímeros , Desenho de Prótese/efeitos adversos , Distribuição Aleatória , Titânio , Suporte de Carga
7.
NMR Biomed ; 31(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29160917

RESUMO

1 H magnetic resonance imaging (MRI) by a zero echo time (ZTE) sequence is an excellent method to image teeth. Calcium phosphate cement (CPC) materials are applied in the restoration of tooth lesions, but it has not yet been investigated whether they can be detected by computed tomography (CT) or MRI. The aim of this study was to optimize high-field ZTE imaging to enable the visualization of a new CPC formulation implanted in teeth and to apply this in the assessment of its decomposition in vivo. CPC was implanted in three human and three goat teeth ex vivo and in three goat teeth in vivo. An ultrashort echo time (UTE) sequence with multiple flip angles and echo times was applied at 11.7 T to measure T1 and T2 * values of CPC, enamel and dentin. Teeth with CPC were imaged with an optimized ZTE sequence. Goat teeth implanted with CPC in vivo were imaged after 7 weeks ex vivo. T2 * relaxation of implanted CPC, dentin and enamel was better fitted by a model assuming a Gaussian rather than a Lorentzian distribution. For CPC and human enamel and dentin, the average T2 * values were 273 ± 19, 562 ± 221 and 476 ± 147 µs, respectively, the average T2 values were 1234 ± 27, 963 ± 151 and 577 ± 41 µs, respectively, and the average T1 values were 1065 ± 45, 972 ± 40 and 903 ± 7 ms, respectively. In ZTE images, CPC had a higher signal-to-noise-ratio than dentin and enamel because of the higher water content. Seven weeks after in vivo implantation, the CPC-filled lesions showed less homogeneous structures, a lower T1 value and T2 * separated into two components. MRI by ZTE provides excellent contrast for CPC in teeth and allows its decomposition to be followed.


Assuntos
Cimentos Ósseos/análise , Fosfatos de Cálcio/análise , Imageamento por Ressonância Magnética , Dente/química , Animais , Dentina/química , Cabras , Humanos , Razão Sinal-Ruído , Fatores de Tempo , Água/química
8.
J Mech Behav Biomed Mater ; 75: 190-196, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28750300

RESUMO

The mechanical reliability of calcium phosphate cements has restricted their clinical application in load-bearing locations. Although their mechanical strength can be improved using a variety of strategies, their fatigue properties are still unclear, especially after degradation. The evolutions of uniaxial compressive properties and the fatigue behavior of calcium phosphate cements incorporating poly (γ-glutamic acid) and its strontium salt after different in vitro degradation times were investigated in the present study. Compressive strength decreased from the 61.2±5.4MPa of the original specimen, to 51.1±4.4, 42.2±3.8, 36.8±2.4 and 28.9±3.2MPa following degradation for one, two, three and four weeks, respectively. Fatigue life under same loading condition also decreased with increasing degradation time. The original specimens remained intact for one million cycles (run-out) under a maximum stress of 30MPa. After degradation for one to four weeks, the specimens were able to withstand maximum stress of 20, 15, 10 and 10MPa, respectively until run-out. Defect volume fraction within the specimens increased from 0.19±0.021% of the original specimen to 0.60±0.19%, 1.09±0.04%, 2.68±0.64% and 7.18±0.34% at degradation time of one, two, three and four weeks, respectively. Therefore, we can infer that the primary cause of the deterioration of the mechanical properties was an increasing in micro defects induced by degradation, which promoted crack initiation and propagation, accelerating the final mechanical failure of the bone cement. This study provided the data required for enhancing the mechanical reliability of the calcium phosphate cements after different degradation times, which will be significant for the modification of load-bearing biodegradable bone cements to match clinical application.


Assuntos
Cimentos Ósseos/análise , Fosfatos de Cálcio/análise , Força Compressiva , Ácido Poliglutâmico/química , Estrôncio/química , Teste de Materiais , Reprodutibilidade dos Testes
9.
J Mech Behav Biomed Mater ; 74: 428-437, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28735216

RESUMO

Calcium phosphate cements (CPCs) should ideally have mechanical properties similar to those of the bone tissue the material is used to replace or repair. Usually, the compressive strength of the CPCs is reported and, more rarely, the elastic modulus. Conversely, scarce or no data are available on Poisson's ratio and strain-to-crack-initiation. This is unfortunate, as data on the elastic response is key to, e.g., numerical model accuracy. In this study, the compressive behaviour of brushite, monetite and apatite cements was fully characterised. Measurement of the surface strains was done using a digital image correlation (DIC) technique, and compared to results obtained with the commonly used built-in displacement measurement of the materials testers. The collected data showed that the use of fixed compression platens, as opposed to spherically seated ones, may in some cases underestimate the compressive strength by up to 40%. Also, the built-in measurements may underestimate the elastic modulus by up to 62% as compared to DIC measurements. Using DIC, the brushite cement was found to be much stiffer (24.3 ± 2.3GPa) than the apatite (13.5 ± 1.6GPa) and monetite (7.1 ± 1.0GPa) cements, and elastic moduli were inversely related to the porosity of the materials. Poisson's ratio was determined to be 0.26 ± 0.02 for brushite, 0.21 ± 0.02 for apatite and 0.20 ± 0.03 for monetite. All investigated CPCs showed low strain-to-crack-initiation (0.17-0.19%). In summary, the elastic modulus of CPCs is substantially higher than previously reported and it is concluded that an accurate procedure is a prerequisite in order to properly compare the mechanical properties of different CPC formulations. It is recommended to use spherically seated platens and measuring the strain at a relevant resolution and on the specimen surface.


Assuntos
Cimentos Ósseos/análise , Fosfatos de Cálcio/análise , Teste de Materiais , Apatitas , Força Compressiva , Módulo de Elasticidade
10.
J Mech Behav Biomed Mater ; 72: 252-260, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28505594

RESUMO

Calcium phosphate cements are osteoconductive biomaterials that are widely used for bone repair and regeneration applications, including spinal fusion, vertebroplasty, khyphoplasty, cranioplasty and periodontal surgeries. The flow and deformation behavior (rheology) and injectability of the calcium phosphate bone cements to the treatment site are governed by the setting kinetics of the cement during which the initially flowable, viscous cement paste transforms into a rigid elastic solid. Here time-dependent development of the linear viscoelastic properties of a brushite-forming calcium phosphate cement are characterized and linked to the mechanism and kinetics of the setting reaction and to the injectability window available during the surgical applications of the cement. The setting kinetics is shown to be a function of the deformation conditions that are utilized in rheological characterization, emphasizing the intimate relationships between setting kinetics, particle to particle network formation and deformation history. Furthermore, the preshearing of the calcium phosphate cement prior to injection and temperature are shown to alter the kinetics of the setting reaction and thus to provide additional degrees of freedom for the tailoring of the rheological behavior and injectability of the calcium phosphate cement.


Assuntos
Cimentos Ósseos/análise , Fosfatos de Cálcio/análise , Teste de Materiais , Procedimentos Ortopédicos , Reologia
11.
J Mech Behav Biomed Mater ; 65: 29-41, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27552597

RESUMO

Osteoporotic fractures poses one of the most problematic health issues that affects millions of people by weakening their bones (Osteoporosis). Polymethylmethacrylate (PMMA) cement is usually used to augment the bone and stabilize the fractures. Despite the benefit of using PMMA, it might cause a leakage where the cement undesirably access the surrounding tissues or vessels and lead to a serious complications. Consequently, it is important to study the leakage phenomenon and associated geometric and operation interactions. Although the experimental leakage models have been reported in many studies, a representative numerical leakage model is not exist. Therefore, the objectives of the present paper are to: (a) to develop and validate a representative numerical leakage model; and (b) to investigate numerically and analytically the importance of the rheological parameters (viscosity and relaxation time) on the cement flow to reduce the risk of leakage. ANSYS Polyflow was utilized to implement a 2D numerical leakage model to study the interaction of complex rheological parameters of the cement with the operational and geometrical structure of the representative porous media. In this model, the cement (represented by the upper-convected Maxwell model) flows from the entrance (tip of an 8 gauge cannula) through a porous media with a leakage path (blood vessels) toward the output (Bottom side). The verified and validated numerical leakage model showed the importance of the elastic and viscous part of the cement to control the uniformity of the distributed cement and augmentation pressure, respectively. Moreover, increasing the flow rate can lead to reduce the risk of leakage since the elastic effect will increase. Geometrical parameters of the porous media has a minor effect on changing the elasticity and subsequently on the uniformity of the distributed cement. In conclusion, Cement rheological parameters are found to be the most influential parameters to reduce the risk of leakage by controlling the uniformity of the distributed cement and the augmentation pressure.


Assuntos
Cimentos Ósseos/análise , Osteoporose/terapia , Polimetil Metacrilato/análise , Substâncias Viscoelásticas/análise , Humanos , Modelos Teóricos , Porosidade , Reologia
12.
Biomed Res Int ; 2016: 7901562, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27812530

RESUMO

Polymethylmethacrylate (PMMA) bone cement is a popular bone void filler for vertebroplasty. However, the use of PMMA has some drawbacks, including the material's excessive stiffness, exothermic polymerization, and short handling time. This study aimed to create an ideal modified bone cement to solve the above-mentioned problems. Modified bone cements were prepared by combining PMMA with three different volume fractions of castor oil (5%, 10%, and 15%). The peak polymerization temperatures, times to achieve the peak polymerization temperature, porosities, densities, modulus and maximum compression strengths of standard (without castor oil), and modified cements were investigated following storage at ambient temperature (22°C) or under precooling conditions (3°C). Six specimens were tested in each group of the aforementioned parameters. Increasing castor oil content and precooling treatment effectively decreased the peak polymerization temperatures and increased the duration to achieve the peak polymerization temperature (P < 0.05). Furthermore, the mechanical properties of the material, including density, modulus, and maximum compression strength, decreased with increasing castor oil content. However, preparation temperature (room temperature versus precooling) had no significant effect (P > 0.05) on these mechanical properties. In conclusion, the addition of castor oil to PMMA followed by precooling created an ideal modified bone cement with a low modulus, low polymerization temperature, and long handling time, enhancing its applicability and safety for vertebroplasty.


Assuntos
Cimentos Ósseos/síntese química , Óleo de Rícino/química , Polimetil Metacrilato/química , Vertebroplastia/métodos , Adesividade , Cimentos Ósseos/análise , Força Compressiva , Módulo de Elasticidade , Dureza , Teste de Materiais , Polímeros/síntese química , Polimetil Metacrilato/análise , Estresse Mecânico , Temperatura , Resistência à Tração , Fatores de Tempo
13.
Med. oral patol. oral cir. bucal (Internet) ; 20(5): e525-e531, sept. 2015. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-142979

RESUMO

BACKGROUND: Many researchers have tried to enhance materials functions in different aspects of science using nano-modification method, and in many cases the results have been encouraging. To evaluate the histopathological responses of the micro-/nano-size cement-type biomaterials derived from calcium silicate-based composition with addition of nano tricalcium aluminate (3CaO.Al2 O3 ) on bone healing response. MATERIAL AND METHODS: Ninety mature male rabbits were anesthetized and a bone defect was created in the right mandible. The rabbits were divided into three groups, which were in turn subdivided into five subgroups with six animals each based on the defect filled by: white mineral trioxide aggregate (WMTA), Nano-WMTA, WMTA without 3CaO.Al2 O3 , Nano-WMTA with 2% Nano-3CaO.Al2 O3 , and empty as control. Twenty, forty and sixty days postoperatively the animals were sacrificed and the right mandibles were removed for histopathological evaluations. Kruskal-Wallis test with post-hoc comparisons based on the LSMeans procedure was used for data analysis. RESULTS: All the experimental materials provoked a moderate to severe inflammatory reaction, which significantly differed from the control group (p< 0.05). Statistical analysis of bone formation and bone regeneration data showed significant differences between groups at 40- and 60- day intervals in all groups. Absence of 3CaO.Al2 O3 leads to more inflammation and foreign body reaction than other groups in all time intervals. CONCLUSIONS: Both powder nano-modification and addition of 2% Nano-3CaO.Al2 O3 to calcium silicate-based cement enhanced the favorable tissue response and osteogenesis properties of WMTA based materials


Assuntos
Animais , Coelhos , Nanoestruturas/uso terapêutico , Óxido de Cálcio , Regeneração Óssea/fisiologia , Substitutos Ósseos/análise , Cimentos Ósseos/análise , Cimentos Dentários/análise , Implantação Dentária Endo-Óssea Endodôntica/métodos
14.
An. R. Acad. Farm ; 81(3): 239-246, jul.-sept. 2015. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-146510

RESUMO

La inclusión de antibióticos en el cemento óseo destinado a la fijación mecánica de las prótesis constituye un sistema de liberación local de antibiótico que permite minimizar la prevalencia y la gravedad de las reacciones adversas que pueden desencadenar los fármacos cuando éstos se administran por vía sistémica. El objetivo del trabajo es estudiar el mecanismo y cinética de liberación in vitro de ciprofloxacino y vancomicina incorporados en diferentes cementos óseos comerciales y evaluar la bioactividad mediante un ejercicio de simulación farmacocinética. Se prepararon mezclas de los cementos de estudio con ciprofloxacino clorhidrato y vancomicina (40:0,5:0,5). Los estudios de liberación se realizaron en agitación continua en solución salina de tampón fosfatos, pH = 7,4, durante dos meses a 37ºC. El análisis estadístico de las cantidades de antibiótico liberadas acumuladas y las velocidades de elución se realizó mediante ANOVA. Con el fin estudiar la bioactividad, se realizó una simulación de Monte Carlo. La cantidad total liberada de ciprofloxacino en un periodo de 8 semanas fue de 0,29 ± 0,06 mg desde los cementos Palacos(R), 0,44 ± 0,06mg LimaCMT1(R) y 0,18 ± 0,04 mg Simplex(R). La cantidad total de vancomicina liberada en 24 horas fue de 0,34 ± 0,17mg desde el cemento Palacos(R), 0,68 ± 0,16 mg LimaCMT1(R) y 0,17 ± 0,02 mg Simplex(R). Transcurrido este tiempo la liberación cesó. El estudio de simulación, muestra que durante las primeras 72 horas, la cobertura antibiótica dependería tanto del cemento elegido como de la sensibilidad del microorganismo y el tiempo postquirúrgico. En tiempos posteriores, es de prever que la bioactividad local aumente


Antibiotic loaded bone cement used in prosthesis fixing, is a local release form that minimizes the prevalence and the complications that the antibiotics would unleash when administered intravenously. The aim of this work is to study in vitro release kinetics of ciprofloxacin and vancomycin loaded in different commercial cements and evaluate the bioactivity through a simulation exercise pharmacokinetics. Samples were prepared with commercial bone cement and ciprofloxacin and vancomycin hydrochloride (40:0,5:0,5). Release study were carried out under stirring in phosphate buffer, pH=7,4, for two months at 37ºC. The antibiotic amount and elution rate, were compared using ANOVA. In order to study the bioactivity, Monte Carlo simulation was performed. The ciprofloxacin released from samples for 8 weeks was 0.29 ± 0.06 mg from the Palacos(R) cements, 0.44 ± 0.06 mg from LimaCMT1® and 0.18 ± 0.04 mg from Simplex(R). The vancomycin released for 24 hours was 0.34 ± 0.17 mg from Palacos(R) cement, 0.68 ± 0.16 mg from LimaCMT1(R) and 0.17 ± 0.02 mg from Simplex(R). After this time the release stopped. The simulation study shows that during the first 72 hours, the antibiotic coverage would depends on the bone cement, the sensitivity of the microorganism and postoperative day. At subsequence times, it is expected that local bioactivity increases


Assuntos
Cimentos Ósseos/análise , Cimentos Ósseos/química , Cimentos Ósseos/farmacologia , Vancomicina/análise , Vancomicina/farmacologia , Vancomicina/uso terapêutico , Antibacterianos/análise , Antibacterianos/farmacologia , Fluoroquinolonas/farmacologia , Fluoroquinolonas/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Sistemas de Liberação de Medicamentos/normas , Análise de Variância , Técnicas In Vitro/métodos , Técnicas In Vitro/normas , Técnicas In Vitro
15.
Mater Sci Eng C Mater Biol Appl ; 51: 107-16, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25842114

RESUMO

This work presents the rheological assessment of poly(methyl methacrylate) (PMMA) polymers synthesized in a dedicated pilot-scale plant. This material is to be used for the construction of scaffolds via Rapid Prototyping (RP). The polymers were prepared to match the physical and biological properties required for medical applications. Differential Scanning Calorimetry (DSC) and Size Exclusion Chromatography (SEC) measurements verified that the synthesized polymers were atactic, amorphous and linear in chains. Rheological properties such as viscosity, storage and loss modulus, beyond the loss factor, and creep and recovery were measured in a plate-plate sensor within the viscoelastic linear region. The results showed the relevant influence of the molecular weight on the viscosity and elasticity of the material, and how, as the molecular weight increases, the viscoelastic properties are getting closer to those of human bone. This article demonstrates that by using the implemented methodology it is possible to synthesize a polymer, with properties comparable to commercially-available PMMA.


Assuntos
Materiais Biocompatíveis/síntese química , Cimentos Ósseos/síntese química , Polimetil Metacrilato/síntese química , Materiais Biocompatíveis/análise , Cimentos Ósseos/análise , Módulo de Elasticidade , Temperatura Alta , Teste de Materiais , Peso Molecular , Projetos Piloto , Polimetil Metacrilato/análise , Pressão , Viscosidade
16.
J Arthroplasty ; 30(8): 1464-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25795235

RESUMO

As the use of cement remains prevalent in orthopedic surgery, so do concerns over the safety of its active ingredient, methyl methacrylate (MMA). The Occupational Health and Safety Agency (OSHA) limits the airborne exposure to 100 parts per million (ppm) averaged over an 8 hour period. We measured MMA exposure to operating room personnel during simulated total hip arthroplasty (THA), antibiotic bead fabrication and simulated spill of MMA. Cumulative and peak exposures during simulated THA and antibiotic bead fabrication did not exceed OSHA limits of 100ppm. Vacuum mixing and greater distance from the vapor source reduced measured MMA exposure. Spilled MMA led to prolonged and elevated MMA levels. MMA levels returned to a negligible level in all scenarios by 20 minutes after mixing.


Assuntos
Poluentes Ocupacionais do Ar/análise , Cimentos Ósseos/análise , Monitoramento Ambiental , Exposição por Inalação , Exposição Ocupacional , Polimetil Metacrilato/análise , Ar/análise , Artroplastia de Quadril , Humanos , Salas Cirúrgicas , Volatilização
17.
Rev. esp. cir. oral maxilofac ; 36(2): 64-67, abr.-jun. 2014. ilus
Artigo em Espanhol | IBECS | ID: ibc-122805

RESUMO

Introducción: El escalón producido en el reborde mandibular en las osteotomías sagitales de avance puede corregirse mediante el uso de una pasta de fosfato cálcico. Material y método: Han sido tratados mediante esta técnica 48 casos, con un seguimiento de al menos 6 meses. Resultados: Han presentado 4 casos infección en el lecho quirúrgico en donde se empleó el fosfato cálcico. Conclusión: Hydroset ha demostrado mejorar la estabilidad en osteotomías de avance mandibular y un buen comportamiento a la hora de evitar los escalones inestéticos en el reborde (AU)


Introduction: An unaesthetic dent in the jawline can be avoided by the reconstruction of the bilateral sagittal split osteotomy (BSSO) defect with calcium phosphate paste. Material and method: A total of 48 cases were treated using the same technique, and followed up for at least 6 months. Results: Infection was present in 4 cases. Conclusion: The calcium phosphate paste (Hydroset) added clinical stability to the lengthening and performed as expected to avoid interruptions in the jawline (AU)


Assuntos
Humanos , Cimentos Ósseos/análise , Cimentos Dentários/análise , Osteotomia Mandibular/métodos , Durapatita/análise , Avanço Mandibular/métodos , Procedimentos Cirúrgicos Ortognáticos/métodos
18.
Ann Occup Hyg ; 58(4): 493-500, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24567286

RESUMO

Poly-methyl methacrylate bone cements contain methyl methacrylate (MMA), which is known for its sensitizing and toxic properties. Therefore, in most European countries and in the USA, guidelines or regulations exist for occupational exposures. The use of vacuum mixing systems can significantly reduce airborne MMA concentrations during bone setting. Our goal was to test two commonly used vacuum mixing systems (Palamix(®) and Optivac(®)) using Palacos(®) R bone cement for their effectiveness at preventing MMA vapor release in a series of standardized trials in a laboratory as well as in an operating theatre. MMA was quantified every second over a period of 3 min using a photoionization detector (MiniRAE(®) 3000) device positioned in the breathing area of the user. Significant differences in MMA mean vapor concentrations over 180 s were observed in the two experimental spaces, with the highest mean concentrations (7.61 and 7.98 ppm for Palamix(®) and Optivac(®), respectively) observed in a laboratory with nine air changes per hour and the lowest average concentrations (1.06 and 1.12 ppm for Palamix(®) and Optivac(®), respectively) in an operating theatre with laminar flow ventilation and 22 air changes per hour. No significant differences in overall MMA concentrations were found between the two vacuum mixing systems in either location. Though, differences were found between both systems during single mixing phases. Thus, typical handling of MMA in orthopedic procedures must be seen as not harmful as concentrations do not reach the short-term exposure limit of 100 ppm. Additionally, laminar airflow seems to have an influence on lowering MMA concentrations in operation theatres.


Assuntos
Cimentos Ósseos/análise , Exposição por Inalação/análise , Procedimentos Ortopédicos , Polimetil Metacrilato/análise , Vácuo , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Cimentos Ósseos/efeitos adversos , Europa (Continente) , Humanos , Exposição por Inalação/prevenção & controle , Salas Cirúrgicas , Polimetil Metacrilato/efeitos adversos , Níveis Máximos Permitidos
20.
Injury ; 44(10): 1327-32, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23769470

RESUMO

INTRODUCTION: Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. MATERIALS AND METHODS: Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. RESULTS: The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. DISCUSSION AND CONCLUSION: The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality could be more effective in enhancing the primary stability of a proximal humerus locking plate because the effect of augmentation can be exploited more effectively limiting it to the degree required.


Assuntos
Cimentos Ósseos/análise , Placas Ósseas/estatística & dados numéricos , Parafusos Ósseos/estatística & dados numéricos , Fixação Interna de Fraturas/métodos , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Densidade Óssea , Cadáver , Feminino , Fixação Interna de Fraturas/instrumentação , Humanos , Masculino , Osteoporose/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...